Counterbalance Valve Performance

Setting Pressure

Page 10 of 10
Previous page, Alt B-Return

 

 

Last Updated
2008:06:19

 


In association with
British Fluid Power Association

 

 

The setting specified for a counterbalance valve is always the cracking pressure.

Setting Pressure

The setting of the valve is always a cracking pressure and should be about 30% above the maximum load pressure. This is because the valve has a hysteresis ( the difference between the reseating pressure to a leakage of less than 5 drops/min and the cracking pressure setting ) of about 85% and it is important that the valve closes fully.

 