If none of the above alternative solutions solve the general instability, there are modifications to the circuit which may help.

Other possible solutions

1. Adding a very small accumulator into the pilot line of the counterbalance valve helps to dampen changes in the pilot signal.

2. Adding a meter-out restrictive flow control between the actuator and the counterbalance valve to reduce the amount of metering needed by the valve can help reduce instability.

3. Adding a small direct operated relief valve to the pilot line to limit the maximum pilot pressure to help to prevent over opening with high inertia loads. It would also require a small restrictor in the line to limit the flow to the relief valve.

 


Introduction | Safety | Fundamentals | Performance | CB Features | PO chk feat. | App Advice | Probs, Solns | Top